Home Cosmetic Science Talk Formulating All Tech-transfer cleansers failing 50C

  • All Tech-transfer cleansers failing 50C

    Posted by MsCheddar on February 2, 2022 at 3:34 pm

    We’ve recently received tech transfers for a handful of cleansers: a liquid cleanser that pairs with a foamer, a gel cleanser, and a cleansing shave cream.

    Each of their benchmarks have separated in 50C. Each product was formulated by a different lab. Is this normal? Do cleansers often have issues passing 50C?

    chemicalmatt replied 2 years, 9 months ago 3 Members · 2 Replies
  • 2 Replies
  • Microformulation

    Member
    February 2, 2022 at 6:10 pm

    50C may be high. We test at 40C, 65% RH (most products).

  • chemicalmatt

    Member
    February 9, 2022 at 9:58 pm

    50C is very high as @Microformulation (Mark) says, @MsCheddar. I’ve been told that 50C temp for accelerated stability arises from an ASTM method used in pharma and unfortunately adapted by personal care formulators. Mark is right, 40C is fine and I usually run at 43C / 65% RH, no higher.